← Back to ODKI
Accuracy and validation

How accurate is ODKI-VBT?

Status: not yet validated

We haven't measured ODKI-VBT against a reference yet, so we don't publish any accuracy figure. Validation is roadmap stage 05, in progress. The method is public before the results, and the raw data will be published whatever it shows.

Last updated: 26 October 2026
1 · What it measures

Vertical bar movement, per rep.

The sensor tracks motion along the vertical axis in the world frame. For each rep it reports peak and mean velocity, peak and mean acceleration, displacement, plus peak and mean velocity of the eccentric phase.

Measured
Vertical velocity, acceleration and displacement, per rep
Not measured
Horizontal bar path, bar tilt, mean propulsive velocity
Mounting
Magnets on a steel bar; non-magnetic bars won't hold it
Firmware
v3.11.31
2 · How the number is made

The IMU is read at 416 Hz and averaged to 100 Hz. A Madgwick filter estimates orientation, so acceleration can be rotated into the world frame and integrated into velocity. Velocity is never force-reset: drift is measured during brief moments of stillness and removed retroactively, so a rep's numbers can be refined after it ends. Every stage is documented in the firmware docs ↗.

3 · Per-rep indicators
Signal-consistency score (0–100)

A self-check

It compares the rep's integrated displacement with its mean velocity × duration. A low score flags a rep worth a second look. It is a signal-consistency score, not an accuracy estimate: a uniform scale error, for example, would leave it at 100. Whether it predicts the error will be tested in the validation.

Correction status

Final or not yet

Each rep says whether its numbers are provisional or already drift-corrected and final.

Raw log

Reproducible

Over USB, every sample is logged at 100 Hz. A Python viewer and a replay tool that runs the real tracking engine are in the repo ↗.

4 · Validation method

Compared with a linear encoder.

A summary. The full protocol, with the acceptance thresholds fixed before any data is collected, is in the public repo.

Read the full protocol ↗

5 · What we'll publish
  • The paired raw data, ODKI and encoder, for every rep
  • The analysis scripts, so anyone can rerun them
  • Results by lift and by velocity range, including where it does badly
  • The firmware version used for every number
  • An open dataset under CC BY 4.0

No results date yet: we'll add one only when we can keep it. Until results are out, this page and the rest of the site don't describe ODKI-VBT as accurate, precise or validated.

6 · Labs and universities

Run a lab with an encoder or motion capture?

Co-validate ODKI-VBT with us using the same published protocol. Results are published openly, whatever they show.

Co-validate it with us

7 · Changes to this page
26 Oct 2026
First version: status, method summary, what we'll publish.